ERFAHRUNGS-BLOG.DE ≡ Pet Shirts V-10 Flats Mens
  • Instruments

  • Benchtop pH meter HI2211

Benchtop pH meter HI2211

$65.26 $124.65
Description:Benchtop pH meter HI2211 pH Range -2.00 to 16.00 pH pH Resolution 0.01 pH pH Accuracy ±0.01 pH pH Calibration automatic, one or two-point with five memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01) pH Temperature Compensation automatic or manual from -9.9 to 120.0°C pH Input impedence 10¹² Ohms mV Range ±399.9 mV ; ±2000 mV mV Resolution 0.1 mV; 1 mV mV Accuracy ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV) Temperature Range -9.9 to 120.0°C (14.2 to 248.0°F) Temperature Resolution 0.1 °C Temperature Accuracy ±0.5 °C (0.0 – 100.0 °C); ±1 °C (outside) Input Channels HI1131B glass body pH electrode with BNC connector Temperature Probe HI7662 stainless steel temperature probe Power Supply 12 VDC adapter (included) Environment 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing Dimensions 240 x 182 x 74mm (9.4 x 7.1 x 2.9”) Ordering Information HI2211 is supplied with HI1131B pH electrode, HI7662 temperature probe, HI76404N electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7082 electrolyte solution, HI700601 cleaning solution sachet, 12 VDC adapter, and instructions.   Word count: 312 Draft saved at 8:11:23 pm. Last edited by Bright Admin on August 11, 2025 at 9:10 am Move upMove downToggle panel: Product image   The HI2211 is a basic affordable  Benchtop pH meter HI2211pH/mV benchtop meter. Operation is simplified to calibration, mode selection (pH or mV), and a last stored reading feature. The HI2211 has a selection to choose between pH and mV modes. The mV mode is used with an optional ORP electrode that is used to check the oxidation or reduction potentials of a solution. Hanna offers a variety of ORP electrodes from glass to PEI plastic body styles. The mV mode of the HI2211 is also useful in checking the offset and slope of the pH electrode. Understanding the offset and slope characteristic is helpful in knowing if the probe is functioning correctly. The HI2211 has a separate inputs for a BNC pH electrode and thermistor temperature probe. The BNC connector is a universal connector that is commonly available and allows the user to select from a wide variety of pH and ORP electrodes for their particular application. The separate temperature probe provides for a high 0.5°C accuracy measurement for precise temperature compensation.
Instruments

Instruments

  • Best Grain Moisture Meter GMM mini Poland in 2025
    $47.59 $87.09
  • Bunsen Burner India
    $42.34 $68.59
  • BOD Sensor Velp
    $48.82 $92.76
  • Benchtop pH meter HI2211
    $65.26 $124.65

© 2026 - ERFAHRUNGS-BLOG.DE